product

Factory Outlets AOAC valid Test Kit - HoneyGuard Tetracyclines Test Kit – kwinbon

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our well-equipped facilities and exceptional good quality manage throughout all stages of production enables us to guarantee total shopper satisfaction for Egg test , Trimethoprem Residue ELISA Kit , Shrimp Safety Test Kit , Standing still today and looking into the future, we sincerely welcome customers all over the world to cooperate with us.
Factory Outlets AOAC valid Test Kit - HoneyGuard Tetracyclines Test Kit – kwinbon Detail:

Cat. KB01009K-50T

About
This kit is used for rapid qualitative analysis of tetracyclines in honey sample.

Sample prepare method
(1) If the honey sample crystallized ,warm it in water bath not high than 60℃, till the honey sample thaw ,mix completely ,cooling as room temperature , then weight for assay.
(2) Weigh 1.0±0.05g homogenate into a 10ml polystyrene centrifuge tube, add 3ml sample extraction solution, vortex for 2min or shake it by hand until the sample is mixed completely.

Assay operations.
(1.) Take bottles needed from the kit package, take out required cards, and make proper marks. Please use these test cards within 1h after open package.
(2.) Take 100l prepared sample into the sample hole by pipette, then start the timer after liquid flow.
(3.) Incubate for 10min at room temperature.
7.LOD

Tetracyclines

LOD(μg/L)

Tetracyclines

LOD(μg/L)

tetracycline

10

doxycycline 15
aureomycin

20

oxytetracycline

10

Results
There are 2 lines in the card result area, Control line and Tetracylcines Line, which are briefly  sed as “B” and “T”. The test results will depend on the color of these lines. The following diagram describes the result identification.
Negative: Control line and Test line both are red and T Line is darker than the control line;
Tetracyclines Positive: Control Line is red, T Line has no color or T Line is lighter color than C line, or the T Line is the same as C Line.

Results

Storage
2-30°C in dark dry place, do not freeze. The kit will be valid in 12 months. The lot number and expired date are printed on the package.


Product detail pictures:

Factory Outlets AOAC valid Test Kit - HoneyGuard Tetracyclines Test Kit – kwinbon detail pictures

Factory Outlets AOAC valid Test Kit - HoneyGuard Tetracyclines Test Kit – kwinbon detail pictures

Factory Outlets AOAC valid Test Kit - HoneyGuard Tetracyclines Test Kit – kwinbon detail pictures


Related Product Guide:

Fast and great quotations, informed advisers to help you choose the correct product that suits all your preferences, a short creation time, responsible top quality control and different services for paying and shipping affairs for Factory Outlets AOAC valid Test Kit - HoneyGuard Tetracyclines Test Kit – kwinbon , The product will supply to all over the world, such as: Swedish, Croatia, Naples, We adopted technique and quality system management, based on "customer orientated, reputation first, mutual benefit, develop with joint efforts", welcome friends to communicate and cooperate from all over the world.
  • In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
    5 Stars By Andrew Forrest from Philippines - 2018.09.21 11:01
    After the signing of the contract, we received satisfactory goods in a short term, this is a commendable manufacturer.
    5 Stars By Julie from Los Angeles - 2018.06.18 19:26
    Write your message here and send it to us