product

Factory source Veratox for Aflatoxin - HoneyGuard Tetracyclines Test Kit – kwinbon

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Good quality comes to start with; service is foremost; organization is cooperation" is our enterprise philosophy which is regularly observed and pursued by our firm for USDA approved Test Kit , BallyBio , Ractopamine test kit , Good quality would be the key factor to the company to stand out from other competitors. Seeing is Believing, want far more info? Just trial on its items!
Factory source Veratox for Aflatoxin - HoneyGuard Tetracyclines Test Kit – kwinbon Detail:

Cat. KB01009K-50T

About
This kit is used for rapid qualitative analysis of tetracyclines in honey sample.

Sample prepare method
(1) If the honey sample crystallized ,warm it in water bath not high than 60℃, till the honey sample thaw ,mix completely ,cooling as room temperature , then weight for assay.
(2) Weigh 1.0±0.05g homogenate into a 10ml polystyrene centrifuge tube, add 3ml sample extraction solution, vortex for 2min or shake it by hand until the sample is mixed completely.

Assay operations.
(1.) Take bottles needed from the kit package, take out required cards, and make proper marks. Please use these test cards within 1h after open package.
(2.) Take 100l prepared sample into the sample hole by pipette, then start the timer after liquid flow.
(3.) Incubate for 10min at room temperature.
7.LOD

Tetracyclines

LOD(μg/L)

Tetracyclines

LOD(μg/L)

tetracycline

10

doxycycline 15
aureomycin

20

oxytetracycline

10

Results
There are 2 lines in the card result area, Control line and Tetracylcines Line, which are briefly  sed as “B” and “T”. The test results will depend on the color of these lines. The following diagram describes the result identification.
Negative: Control line and Test line both are red and T Line is darker than the control line;
Tetracyclines Positive: Control Line is red, T Line has no color or T Line is lighter color than C line, or the T Line is the same as C Line.

Results

Storage
2-30°C in dark dry place, do not freeze. The kit will be valid in 12 months. The lot number and expired date are printed on the package.


Product detail pictures:

Factory source Veratox for Aflatoxin - HoneyGuard Tetracyclines Test Kit – kwinbon detail pictures

Factory source Veratox for Aflatoxin - HoneyGuard Tetracyclines Test Kit – kwinbon detail pictures

Factory source Veratox for Aflatoxin - HoneyGuard Tetracyclines Test Kit – kwinbon detail pictures


Related Product Guide:

Assume full responsibility to satisfy all needs of our clients; achieve continual advancements by endorsing the expansion of our purchasers; turn into the final permanent cooperative partner of clientele and maximize the interests of clients for Factory source Veratox for Aflatoxin - HoneyGuard Tetracyclines Test Kit – kwinbon , The product will supply to all over the world, such as: Turin, Netherlands, Estonia, Our Company policy is "quality first, to be better and stronger, sustainable development" . Our pursuit goals is "for society, customers, employees, partners and enterprises to seek reasonable benefit". We aspirate to do cooperate with all different the auto parts manufacturers, repair shop, auto peer , then create a beautiful future! Thank you for taking time to browse our website and we would welcome any suggestions you may have that can help us to improve our site.
  • This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Jamie from Manila - 2017.04.08 14:55
    This company conforms to the market requirement and joins in the market competition by its high quality product, this is an enterprise that have Chinese spirit.
    5 Stars By Julie from Orlando - 2017.09.28 18:29
    Write your message here and send it to us