We normally think and practice corresponding towards the change of circumstance, and grow up. We aim at the achievement of a richer mind and body plus the living for Toxoplasma Ab test kit , Ochratoxin A Testing , NeoColumn , We are sincerely looking forward to cooperate with customers all over the world. We believe we can satisfy you. We also warmly welcome customers to visit our company and purchase our products.
Reasonable price Tetracycline residue test kit - Elisa Test Kit of Aflatoxin B1 – kwinbon Detail:

Large doses of aflatoxins lead to acute poisoning (aflatoxicosis) that can be life threatening, usually through damage to the liver.
Aflatoxin B1 is an aflatoxin produced by Aspergillus flavus and A. parasiticus. It is a very potent carcinogen. This carcinogenic potency varies across species with some, such as rats and monkeys, seemingly much more susceptible than others. Aflatoxin B1 is a common contaminant in a variety of foods including peanuts, cottonseed meal, corn, and other grains; as well as animal feeds. Aflatoxin B1 is considered the most toxic aflatoxin and it is highly implicated in hepatocellular carcinoma (HCC) in humans.[citation needed] In animals, aflatoxin B1 has also been shown to be mutagenic, teratogenic, and to cause immunosuppression. Several sampling and analytical methods including thin-layer chromatography (TLC), high-performance liquid chromatography (HPLC), mass spectrometry, and enzyme-linked immunosorbent assay (ELISA), among others, have been used to test for aflatoxin B1 contamination in foods. According to the Food and Agriculture Organization (FAO), the worldwide maximum tolerated levels of aflatoxin B1 was reported to be in the range of 1–20 μg/kg in food, and 5–50 μg/kg in dietary cattle feed in 2003.

Details

1.Elisa Test Kit for Aflatoxin B1

2.Cat. KA07202H-96wells

3. Kit components
● Microtiter plateprecoated with antigen, 96 wells
● Standard Solution ×6bottle(1ml/bottle)
0ppb, 0.02ppb, 0.06ppb, 0.18ppb, 0.54ppb,1.62ppb
● Enzyme conjugate 7ml………………………………………………………..…………red cap
● Antibody solution7ml..................................................................................………green cap
● Substrate A 7ml………………………………………………………….…………...…white cap
● Substrate B 7ml……………….……………………………………………….…………red cap
● Stop solution 7ml……….…….………………………………………………..………yellow cap
● 20×concentrated wash solution 40ml …………………………………………transparent cap
● 2×concentrated extraction solution 50ml………………………………………………blue cap

4.Sensitivity, accuracy and precision
Sensitivity: 0.05ppb

5.Detection limit
Edible oil sample.........................................................................................................................0.1ppb
Peanut..........................................................................................................................0.2ppb
Cereal.........................................................................................................................0.05ppb
Accuracy
Edible oil sample.....................................................................................................................80±15%
Peanut........................................................................................................................80±15%
Cereal........................................................................................................................80±15%
Precision: Variation coefficient of the ELISA kit is less than 10%.

6.Cross Rate
Aflatoxin B1·················100%
Aflatoxin B2·······················81 .3%
Aflatoxin G1·······················62%
Aflatoxin G2·······················22.3%


Product detail pictures:

Reasonable price Tetracycline residue test kit - Elisa Test Kit of Aflatoxin B1 – kwinbon detail pictures

Reasonable price Tetracycline residue test kit - Elisa Test Kit of Aflatoxin B1 – kwinbon detail pictures


Related Product Guide:

Our organization insists all along the quality policy of "product quality is base of business survival; purchaser gratification is the staring point and ending of an business; persistent improvement is eternal pursuit of staff" as well as the consistent purpose of "reputation 1st, purchaser first" for Reasonable price Tetracycline residue test kit - Elisa Test Kit of Aflatoxin B1 – kwinbon , The product will supply to all over the world, such as: Maldives, United States, Amsterdam, Item have passed by means of the national qualified certification and been well received in our main industry. Our expert engineering team will often be ready to serve you for consultation and feedback. We are able to also deliver you with cost-free samples to meet your specifications. Ideal efforts will probably be produced to provide you the most beneficial service and solutions. Should you be interested in our company and solutions, please make contact with us by sending us emails or call us straight away. To be able to know our solutions and enterprise. ar more, you'll be able to come to our factory to see it. We'll constantly welcome guests from all over the world to our firm. o build business enterprise. elations with us. Please feel absolutely free to speak to us for organization. nd we believe we will share the best trading practical experience with all our merchants.
  • The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
    5 Stars By Philipppa from St. Petersburg - 2018.09.21 11:01
    The customer service reprersentative explained very detailed, service attitude is very good, reply is very timely and comprehensive, a happy communication! We hope to have a opportunity to cooperate.
    5 Stars By Janet from Philadelphia - 2017.06.16 18:23
    Write your message here and send it to us