product

Short Lead Time for Igg Elisa Test - Elisa Test Kit of AMOZ – kwinbon

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We pursue the management tenet of "Quality is remarkable, Company is supreme, Name is first", and will sincerely create and share success with all clientele for Unisensor , Servsafe Test , Ivermectin Test Kit , All of the time, we have been paying attention on all information to insure each product or service glad by our customers.
Short Lead Time for Igg Elisa Test - Elisa Test Kit of AMOZ – kwinbon Detail:

2.The nitrofuran drugs furaltadone, nitrofurantoin and nitrofurazone were banned from use in food animal production in the EU in 1993, and the use of furazolidone was prohibited in 1995. The analysis of nitrofuran drugs residue needs to be based on the detection of the tissue bound metabolites of the nitrofuran parent drugs, since the parent drugs are very rapidly metabolized, and the tissue bound nitrofuran metabolites will retain for a long time, therefore the metabolites are used as the target in the detection of the abuse of nitrofurans. Furazolidone metabolite (AMOZ), Furaltadone metabolite (AMOZ), Nitrofurantoin metabolite (AHD) and Nitrofurazone metabolite (SEM).

Details

1.Elisa Test Kit of AMOZ

2.Cat. KA00205H-96 Wells

3.Kit Components
● Microtiter plate with 96 wells coated with antigen
● Standard solutions(6 bottles)
0ppb, 0.05ppb,0.15ppb,0.45ppb,1.35ppb,4.05ppb
● Spiking standard solution: (1ml/bottle) ……………………………………………...100ppb
● Enzyme conjugate 1ml…………………………………………………..…………….red cap
● Antibody solution 7ml ………………………………………………..………….….green cap
● solution A 7ml…………………………………………………….…………………white cap
● solution B 7ml………………………………………………………….………..…… red cap
● stop solution 7ml ……………………………………………………….…………yellow cap
● 20×concentrated wash solution 40ml…………………………………….……transparent cap
● 2×concentrated extraction solution 50ml……………………………………….…….blue cap
● 2-Nitrobenzaldehyde 15.1mg………………………………………………….……white cap

4.Sensitivity, accuracy and precision
Sensitivity: 0.05ppb
Detection limit
Aquatic products(fish and shrimp)………….……… 0.1ppb
Accuracy
Aquatic products(fish and shrimp)….…...………… 95±25%
Precision: CV of the ELISA kit is less than 10%.

5.Cross Rate
Furaltadone metabolite(AMOZ)………………………………….…………100%
Furazolidone metabolite(AMOZ)…………………………..………………..<0.1%
Nitrofurantoin metabolite(AHD)……………………………….……………<0.1%
Nitrofurazone metabolite(SEM)…………………………………………..…<0.1%
Furaltadone…………………………………………………………….…….11.1%
Furazolidone……………………………………………………….….…..…<0.1%
Nitrofurantoin……………………………………………………….…….…<1%
Nitrofurazone…………………………………………….………………..…<1%


Product detail pictures:

Short Lead Time for Igg Elisa Test - Elisa Test Kit of AMOZ – kwinbon detail pictures

Short Lead Time for Igg Elisa Test - Elisa Test Kit of AMOZ – kwinbon detail pictures


Related Product Guide:

It truly is a great way to improve our merchandise and repair. Our mission should be to create imaginative products to prospects with a excellent knowledge for Short Lead Time for Igg Elisa Test - Elisa Test Kit of AMOZ – kwinbon , The product will supply to all over the world, such as: Comoros, Bangkok, UK, We integrate design, manufacture and export together with more than 100 skillful workers, strict quality controlling system and experienced technology.We keep long term business relationships with wholesaler and distributors form more than 50 countries, such as USA, UK, Canada, Europe and Africa etc.
  • Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Lindsay from Gambia - 2018.10.31 10:02
    This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
    5 Stars By Cara from Portugal - 2017.09.30 16:36
    Write your message here and send it to us